M Series Software

 

Home
Up
TRiLOGI TBasic
ExcelLink
Internet
Dial-Up
E-Mail Services
TRi Demo Download

TRiLOGI M Series Software

Use the On-Line Programming Tutorial

Try out the Intenet TRiLOGi On-Line Now!

Download Trial TRILOGI Software with TBASIC

1. Insert Element

To add an element to the ladder diagram, you simply press the <Ins> key and pick an item from the Insert Element pull down menu as shown above. This menu lets you create Normally-Open (NO) or Normally-Closed (NC) contacts in series or in parallel. One or more coils can be connected by choosing Item "7" or "8". To insert a special function, select Item "9" or "0" (for multiple function) and the special function menu will appear as described in the next section.

2. Special Functions

bullet[DNctr],[Upctr],[RSctr] - Reversible up/down ring counter functions.
bullet[AVseq],[RSseq],[StepN] - You can advance any one of the 8 sequencers one step at a time or even randomly set the step counter of any sequencer to any integer value between 0 and 31.
bullet[Latch],[Clear] - When activated, the associated output or internal relay will remain ON until it is reset by the [Clear] function acted on the same output or relay.
bullet[Ilock],[ILoff] - This is equivalent to a master relay with sub-branches.
bullet[DIFU],[DIFD] --The associated relay will turn on for one scan time when its execution condition goes from OFF to ON or ON to OFF.
bullet[CusFn] - Execute the Custom Function (1-128) written in TBASIC.
bullet[CusF] - Execute the Custom Function (1-128) for one scan time when the execution condition goes from OFF to ON.

3. Special Bits

bulletSequencer 1 to 8. T100MX supports 8 sequencers with 32 steps each (Step #0 to Step #31).. Each step of the sequencer can be used as a contact in the ladder diagram. E.g. Seq1:5 represents Step #5 , which means that the contact with the name "Seq1:5" will be turned ON when the step counter of the sequencer reaches the value of '5' and will be OFF when the step counter is at any other value.
bulletClock Pulses - Eight clock pulses with periods of 0.01s to 1 minute are available on the T100MX PLC. They can be used as a NO or NC contact in the ladder diagram.
bulletReal Time Clock Error - This flag is used as an indicator that the Real Timer Clock in the PLC has been reset to factory pre-set date and time due to power failure. This warns users that they must set the clock properly if time-scheduled events are required.

4. Edit Custom Function

The custom function editor window allows creation of up to 60 lines of TBASIC program statements. Each line can contain a maximum of 70 characters. The extreme left column of the editor window shows the line number from 1-60. In one screen only 20 lines are visible. You can however easily scroll up and down in pages using the <PgUp>, <PgDn> keys and the cursor keys.

5. Real Time Simulation

While constructing your ladder program you can simulate it using TRiLOGI's unique real-time Simulator. When you invoke the Simulator, you will see a screen of I/Os organized into 7 columns:

The first two columns show Inputs, followed by Timers, Counters/Sequencers, Internal Relays and Outputs. Beside each I/O, an indicator lamp indicates whether the I/O is ON or OFF. You can move the highlight bar to any I/O and press the <Enter> key to toggle its status and the status of all the other I/Os will be immediately updated according to the ladder program. A red "*" symbol means an I/O is ON whereas a grey "." means it is OFF.

In addition, you can view the values of all variables used by TBASIC on the “View Variables” window during simulation:

All 32-bit integer A to Z, A/D, D/A, PWM and Real Time Clock values are grouped into one screen. By pressing the and keys you can scroll to the String Variable screen to display A$ to Z$ and Data Memory screen to display DM[1] to DM[4000].

6. On-Line Monitoring and Control

TRiLOGI can watch in real time the status of all the I/Os, timers, counters and the values of all internal variables within the PLC, It also permits you to pause the PLC and remotely forced-set or reset any I/Os or modify the current value of the timers, counters and any variables.

The I/Os and variables can be monitored on a full screen display similar to the Simulator-screen, and the I/Os status can also be monitored directly on the ladder diagram. This feature helps greatly during debugging and fine-tuning of your PLC program.

7. TBASIC Components:  Statements, Functions and Operators

 

        